The L6-30 twist-lock is the workhorse receptacle of server rooms and mining setups in North America. It is 30A, 250V, and locks so it cannot be pulled out by accident. But the cord you plug into it depends entirely on what is on the other end.
The Valiant Power L6-30P Power Cord comes in three configurations and three lengths. Here is how to pick.
First, what is L6-30P?
NEMA L6-30P is the plug. "L" means locking, "6" means 250V with no neutral (two hots and a ground), and "30" is the amp rating. It goes into an L6-30R receptacle. You push it in and twist clockwise until it locks.
Option 1: L6-30P to C19
Use this when your equipment has a C20 inlet. C20 inlets show up on high-draw gear: large servers, GPU systems, blade chassis, rack UPS units, and many PDUs that accept a C20 input. The C19 end plugs into the C20 inlet, the L6-30P end goes into the wall. One device, one cord, straight from the circuit.
Option 2: L6-30P to Dual C13
Use this to power two devices with C14 inlets from one L6-30R receptacle. It is a splitter: one locking plug, two C13 ends. Handy for a pair of servers or switches when you do not want to add a full PDU.
Each C13 end has its own limit (C13 connectors are rated well below 30A), so this is for two moderate loads, not two heavy ones. For heavier gear, use a PDU with C19 outlets.
Option 3: L6-30P to L6-30R
This is an extension cord. Use it when the device or PDU already has an L6-30P plug but the receptacle is a little too far away. One L6-30P end goes into the wall, the L6-30R end accepts the device plug, and both ends lock. For a heavier-gauge option, see our dedicated 10AWG L6-30P to L6-30R extension cord.
Quick picker
| Your equipment has | Choose |
|---|---|
| A C20 inlet | L6-30P to C19 |
| Two devices with C14 inlets | L6-30P to Dual C13 |
| Its own L6-30P plug that will not reach | L6-30P to L6-30R |
Choosing a length
- 3 ft: receptacle right behind the rack. Least slack, cleanest look.
- 6 ft: the most common choice. Reaches from the top of a rack to a nearby wall or floor receptacle.
- 10 ft: receptacle across the aisle, under a raised floor, or high on the wall.
Shorter is better when it reaches. Extra cable has to be coiled somewhere, and coils in a rack block airflow and make tracing cables harder.
Specs
| Plug | NEMA L6-30P twist-lock |
| Rating | 30A, 250V |
| Wire | 12AWG |
| Other end | C19, Dual C13, or L6-30R |
| Lengths | 3 ft, 6 ft, 10 ft |
Frequently asked questions
Will an L6-30P fit a dryer outlet?
No. Dryer outlets use a different, non-locking connector. You need an L6-30R receptacle.
Can I use the dual C13 version for two miners?
Only if they have C14 inlets and their combined draw stays within the cord and connector ratings. Most current miners draw too much for a C13 connection.
Do these work on 208V?
Yes. They are rated up to 250V, which covers 208 and 240V circuits.