30A Mining PDU Guide: Planning Power for 3 C19 and 8 C13 Outlets

Valiant Power 30A vertical mining PDU with 3 C19 and 8 C13 outlets

Mining racks are hard on power gear. Everything runs flat out around the clock, the fans shake every connection, and one overloaded circuit can take a whole shelf offline. A mining PDU has to give you the right outlets, protect the circuit, and show you the load so you are not guessing.

The Valiant Power 30A Vertical Mining PDU does that with 11 outlets, a 30A breaker, and a live meter.

30A Vertical Mining PDU, 3 C19 + 8 C13

30A Vertical Mining PDU, 3 C19 + 8 C13

$135.00

Buy Now

The outlet layout

  • 3 C19 outlets for miners. Units with C20 inlets connect with a C19 to C20 cord. Newer Antminers with P13 inlets connect with a C20 to P13 cord.
  • 8 C13 outlets for the support gear: switches, routers, controllers, fans, monitoring. These use standard C13 to C14 cords.

7,200 watts, and what that means for miners

The PDU is rated at 7,200 watts, which is 30A at 240V. That is the maximum. Miners are continuous loads, and continuous loads should stay at or under 80% of the breaker rating. So the number to plan around is 24A, or 5,760 watts at 240V.

Here is how that plays out:

Setup Approx. draw Fits on one 30A circuit?
One miner at 3,300W plus network gear about 3,450W Yes, with room to spare
Two efficient miners at 2,600W each about 5,200W Yes, close to the limit
Two miners at 3,500W each about 7,000W No, needs two circuits

Three C19 outlets give you flexibility, not permission to load three full-power miners on one circuit. Always check the real wall draw at the settings you run, then confirm on the meter.

The meter and breaker

The LCD shows voltage, amps, and kilowatts live. The 30A single pole breaker sits under a clear cover to prevent accidental bumps, and it trips if the strip is overloaded.

Specs

Outlets 3 x C19, 8 x C13
Rating 30A, 230 to 240V (7,200W)
Plug NEMA L6-30P twist-lock, 6 ft cord
Metering Volts, amps, kW
Protection 30A single pole breaker
Housing Reversible metal
SKU VP-PDU-30A-V-8184

Mounting

The reversible metal housing mounts vertically or horizontally: on a rack, a wall, a workbench, or under a counter. In shelf-style mining setups, mount it vertically along the shelf post so each miner's cord runs straight across, away from the hot exhaust.

Running from a generator

The PDU runs on 230 to 240V from a utility receptacle, generator, or farm supply. If your generator has an L6-30R outlet, it plugs straight in. If the generator sits farther away, an L6-30 extension cord bridges the gap.

Frequently asked questions

Which miners work with it?

Any miner with a C20 inlet, including L7 and S19 series units, plus P13 miners using a C20 to P13 cord.

Why only a 6 ft cord?

Short cords mean less slack in hot mining spaces. If you need more reach, use a 10AWG extension rather than a thin one.

How do I run more miners?

Add circuits and PDUs, or step up to a 50A metered PDU on a 50A circuit.

30A Vertical Mining PDU, 3 C19 + 8 C13

30A Vertical Mining PDU, 3 C19 + 8 C13

$135.00

Buy Now

Email support@valiantpowerco.com with your miner models and we will help plan the circuit. Or see the 30A Vertical Mining PDU.