Mining racks are hard on power gear. Everything runs flat out around the clock, the fans shake every connection, and one overloaded circuit can take a whole shelf offline. A mining PDU has to give you the right outlets, protect the circuit, and show you the load so you are not guessing.
The Valiant Power 30A Vertical Mining PDU does that with 11 outlets, a 30A breaker, and a live meter.
The outlet layout
- 3 C19 outlets for miners. Units with C20 inlets connect with a C19 to C20 cord. Newer Antminers with P13 inlets connect with a C20 to P13 cord.
- 8 C13 outlets for the support gear: switches, routers, controllers, fans, monitoring. These use standard C13 to C14 cords.
7,200 watts, and what that means for miners
The PDU is rated at 7,200 watts, which is 30A at 240V. That is the maximum. Miners are continuous loads, and continuous loads should stay at or under 80% of the breaker rating. So the number to plan around is 24A, or 5,760 watts at 240V.
Here is how that plays out:
| Setup | Approx. draw | Fits on one 30A circuit? |
|---|---|---|
| One miner at 3,300W plus network gear | about 3,450W | Yes, with room to spare |
| Two efficient miners at 2,600W each | about 5,200W | Yes, close to the limit |
| Two miners at 3,500W each | about 7,000W | No, needs two circuits |
Three C19 outlets give you flexibility, not permission to load three full-power miners on one circuit. Always check the real wall draw at the settings you run, then confirm on the meter.
The meter and breaker
The LCD shows voltage, amps, and kilowatts live. The 30A single pole breaker sits under a clear cover to prevent accidental bumps, and it trips if the strip is overloaded.
Specs
| Outlets | 3 x C19, 8 x C13 |
| Rating | 30A, 230 to 240V (7,200W) |
| Plug | NEMA L6-30P twist-lock, 6 ft cord |
| Metering | Volts, amps, kW |
| Protection | 30A single pole breaker |
| Housing | Reversible metal |
| SKU | VP-PDU-30A-V-8184 |
Mounting
The reversible metal housing mounts vertically or horizontally: on a rack, a wall, a workbench, or under a counter. In shelf-style mining setups, mount it vertically along the shelf post so each miner's cord runs straight across, away from the hot exhaust.
Running from a generator
The PDU runs on 230 to 240V from a utility receptacle, generator, or farm supply. If your generator has an L6-30R outlet, it plugs straight in. If the generator sits farther away, an L6-30 extension cord bridges the gap.
Frequently asked questions
Which miners work with it?
Any miner with a C20 inlet, including L7 and S19 series units, plus P13 miners using a C20 to P13 cord.
Why only a 6 ft cord?
Short cords mean less slack in hot mining spaces. If you need more reach, use a 10AWG extension rather than a thin one.
How do I run more miners?
Add circuits and PDUs, or step up to a 50A metered PDU on a 50A circuit.
Email support@valiantpowerco.com with your miner models and we will help plan the circuit. Or see the 30A Vertical Mining PDU.